Virtual Fault Laboratory

Detect faults you've never measured before.

We build a simulation model of your machine, use it to specifically simulate wear and damage, and provide a diagnosis that runs on your control system: which component is affected and to what extent. Starting from commissioning—not only after years of data collection.

Live Example

Hydraulic Accumulator: Loss of Precharge Pressure

Early warning
Systemdruck Arbeitszyklus →
Target Path (Intact) Current status
35%
Error IndicatorDetection threshold: 20%

Fault detected: The precharge pressure is dropping. Schedule maintenance during the next planned shutdown.

Illustrative example using a generic hydraulic model.

The Problem

Why Predictive Maintenance Hasn't Worked for Your Machine So Far

Not enough machines in the field

With small production runs and custom-built machines, there are never enough failures to train a reliable model.

No one deliberately breaks their machine

Testing for errors on a test bench or in the field is expensive, risky, and often simply not feasible.

No Diagnosis Without Examples of Errors

A target-actual comparison indicates that something is wrong. Data-driven methods can only determine which component is affected and to what extent by analyzing actual errors—those without such data will have to wait.

The result: Diagnosis remains based on empirical knowledge.

Our Approach

Error data you never had to measure

Instead of waiting years for failures to occur, we simulate them in a model: reproducibly, at any severity level, and without risk to people or machines.

Modeling

Your machine and control system as a physical Simulink/Simscape model, calibrated using your data from normal operation.

Incorporate damage

Each failure mode is simulated in the model and can be adjusted continuously from 0 to 100% severity.

Develop a detection method

The detection algorithm is derived from the simulated error signatures—as generated code for your target control system.

Document

The hit rate, false alarm rate, and lead time are measured in the model before the detection system is deployed in the field.

Typical failure modes from our hydraulics library

Internal leak in the cylinder

Loss of precharge pressure in the reservoir

Worn seals

Clogged filter

Sensor drift

Pump wear

Valve Wear

Air in the Oil

Overheating of the hydraulic oil

… and the faults that are unique to your machine

Performance

Complete, removable, fixed-price—per error mode

Each error mode is a self-contained package. You know in advance what you’ll get, when it will be ready, and how you’ll accept it.

Error Model in the Twin

The damage is simulated in your machine’s model and can be adjusted continuously from 0 to 100%.

Error signature

Which existing signals change and how, and at what severity level this becomes measurable.

Recognition Algorithm

Developed in Simulink and generated as code for your target controller.

Verification in the model

Hit rate, false alarm rate, and lead time, measured across defined operational scenarios.

Documentation

Fully traceable from the request to the test result.

Benefits for You

Who in Your Company Will Benefit

Development

Validation Without Degradation Tests

Test diagnostics on the model instead of on the test bench. The code comes directly from the model, and the model remains in use for the next generation of machines.

Diagnosis Instead of Alarm

A target-actual comparison only indicates that something is wrong. We identify which component is affected and to what extent—with a proven success rate.

Service

Plan Operations Instead of Putting Out Fires

Fewer unplanned service calls. The diagnosis identifies the component, so the correct replacement part is on hand for the first service call.

Starting on Day 1, not years later

Detection begins at startup, not only after enough failures have occurred.

Management

New Service Business

The technical basis for availability and service agreements—and a key selling point in requests for proposals.

Your Machine, Your Code

The model, algorithms, and generated code run on your controller. No cloud subscription, no machine data stored with third parties.

Your customers

Less Downtime

A machine that alerts you before it breaks down. Maintenance when it’s needed—not when it’s too late.

Deliver instead of participate

Fixed-price packages with a measurable scope of work, rather than an open-ended project billed on a time-and-materials basis.

Optional: Safety features on the test bench (HiL) and integration into your production control system.

Benefit Analysis

The Value of Early Detection of a Failure

Do the math using your own numbers. We’ll work out the exact calculation together in the error chart.

50%

Avoidable downtime costs per year

€240,000

equals €6,000 per machine in the field

6 breakdowns × €80,000 × 50% detected early

Example figures to start with. Not included: saved test bench time and new service revenue.

Reference

Current Project

For a leading manufacturer of offshore pile-driving technology, we are modeling 17 failure modes of a hydraulic pile driver—without damaging a single pile driver.
Base Model
Fault Injection
Detection
Verification in Simulation

Why Sokratel

Getting Started

Start Small—With a Fixed Price

You make a new decision after each stage. No large-scale project, no open-ended budget.

Recommended Starting Point

Level 1 · 1–4 weeks

Error Map

Two days of workshops at your facility, followed by a week of analysis. Result: Your failure modes, prioritized by failure costs, frequency, and current detectability—including sensor gaps—along with a fixed-price quote for Phase 2.

Level 2 · approx. 6 months

Basic Error Lab

The base model of your machine plus the 3 to 5 most expensive failure modes from your failure tree, including detection, code, and verification.

Level 3 · as needed

Expansion

Each additional error mode is treated as a self-contained package with its own acceptance testing. They expand detection capabilities where it makes economic sense.

FAQ

Frequently Asked Questions

Usually not. We start by working with the signals your control system already has. If a fault cannot be detected using those signals, the fault map shows the missing sensor and what closing that gap would achieve.

Design and control data, as well as measurement data from normal operation. We don’t need error data—we generate that in the model.

The model of your machine, the recognition algorithms, and the generated code belong to you. Our generic tools and libraries remain with us. That’s why we don’t start from scratch on every project.

Not required for operation: The generated code runs on your controller without MATLAB. If you want to further develop the model and detection yourself, you’ll need the appropriate licenses. We provide everything with documentation so your team can work with it.

The fault map will be ready in about three weeks. For the basic package with three to five fault modes, expect it to take about 6 months.

Condition monitoring and anomaly detection reveal when a machine is behaving differently than expected. The failure laboratory provides the underlying diagnosis: which component is affected, to what extent, and at what severity level the failure can be reliably detected—with a proven hit rate. The two approaches complement each other.

Hydraulics is our specialty. The method works for all systems that can be physically modeled, such as actuators, pneumatic systems, thermal systems, or power electronics.

Which outage costs you the most?

In 30 minutes, we’ll work with you to outline the initial failure modes of your machine—and give you our honest opinion on whether the failure analysis lab is worth it for you.

Robert Bartel

Contact Person: Virtual Error Lab

+49 151 27111674

robert.bartel@sokratel.com

Request an Initial Consultation

Scroll to Top